(a)
Interpretation:
The type of noises that can be reduced by decreasing the temperature of measurement needs to be determined.
Concept introduction:
Chemical analyses are related with two types of noise which are chemical noise and instrumental noise. Chemical noise is due to reasons that affect the chemistry of the system being analyzed. Instrumental noise is components of the instrument. There are four types of instrumental noise and they are thermal noise, shot noise, flicker noise and environmental noise.
(b)
Interpretation:
The type of noise that can be reduced by increasing the frequency used for measurement needs to be determined.
Concept introduction:
Chemical analyses are related with two types of noise which are chemical noise and instrumental noise. Chemical noise is due to reasons that affect the chemistry of the system being analyzed. Instrumental noise is components of the instrument. There are four types of instrumental noise and they are thermal noise, shot noise, flicker noise and environmental noise. Among them flicker noise and environmental noise are frequency dependent thermal noise and shot noise are frequency independent.
(c)
Interpretation:
The type of noise that can be reduced by decreasing the band width of the measurement needs to be determined.
Concept introduction:
Radiation does not only come from human-made sources, but it can also come from natural sources.
Trending nowThis is a popular solution!
- Describe the differences and similarities between spontaneous and stimulated emission.arrow_forwardWhat issues experienced with fluorescence detectors are resolved using chemiluminescence detectors?arrow_forwardCan we expect that a plot of relative fluorescence intensity vs. concentration to be linear?arrow_forward
- A 2.0 mm cell was filled with a solution of benzene in a non-absorbing solvent. The concentration of the benzene was 0.010 mol dm−3 and the wavelength of the radiation was 256 nm (where there is a maximum in the absorption). Calculate the molar absorption coefficient of benzene at this wavelength given that the transmission was 48 per cent. What will the transmittance be through a 4.0 mm cell at the same wavelength?arrow_forwardDescribe the mechanisms of fluorescence and phosphorescence. How could you test the proposed mechanisms?arrow_forwardhow can you test fluorescence and phosphorescence mechanismsarrow_forward