Question
Book Icon
Chapter A1, Problem A1.23QAP
Interpretation Introduction

(a)

Interpretation:

The calibration of calcium ion selective electrode is used for the determination of pCa and the table for this data is shown below-

pCa=log[Ca2+] EymV
5.00 -53.8
4.00 -27.7
3.00 +2.7
2.00 +31.9
1.00 +65.1

The relation between potential and the and the pCa is linear. Using the data, a least square straight line is to be plotted using the spreadsheet.

Concept introduction:

The least square method is a method in which the best result is obtained for the set data point by minimizing the sum of offset or residuals from the plot of curve statistically.

Interpretation Introduction

(b)

Interpretation:

The least square expression is to be determined for the best straight line through the point.

Concept introduction:

The least square method is a method in which the best result is obtained for the set data point by minimizing the sum of offset or residuals from the plot of curve statistically.

Interpretation Introduction

(c)

Interpretation:

The standard deviation is to be determined for the slope and the intercept of the least-square line.

Concept introduction:

The slope of line is also called as gradient of line which is used to define the direction and steepness of the line.

The intercept line is the y −axis of line at which point it crosses X −axis.

Interpretation Introduction

(d)

Interpretation:

The value pCa of serum solution is to be determined in which the electrode potential value is 10.7mV. The absolute and relative standard deviation for pCa is to be determined when obtained result is from the single voltage measurement.

Concept introduction:

The standard deviation method is used for the quantification of the amount of variation or for the dispersion for the set of the data values.

Interpretation Introduction

(e)

Interpretation:

The absolute and relative standard deviation for pCa is to be determined when the result obtained from the part (d) in millimeters is the mean value of two replicate measurements and this calculation is to be repeated for the eight measurements.

Concept introduction:

The standard deviation method is used for the quantification of the amount of variation or for the dispersion for the set of the data values.

Blurred answer
Students have asked these similar questions
Why is SHE considered as the standard electrode?
why the reference electrode can serve as a probe to measure relativereduction potentials or even detect a change in pH of solution
Provide as many error sources in your calibration of the ion-selective electrode (ISE) as you can.
Knowledge Booster
Background pattern image
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Text book image
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:9781285640686
Author:Skoog
Publisher:Cengage
Text book image
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:9781285686691
Author:Crouch
Publisher:Cengage