A combined gas–steam power cycle uses a simple gas turbine for the topping cycle and simple Rankine cycle for the bottoming cycle. Atmospheric air enters the gas turbine at 101 kPa and 20°C, and the maximum gas cycle temperature is 1100°C. The compressor pressure ratio is 8; the compressor isentropic efficiency is 85 percent; and the gas turbine isentropic efficiency is 90 percent. The gas stream leaves the heat exchanger at the saturation temperature of the steam flowing through the heat exchanger. Steam flows through the heat exchanger with a pressure of 6000 kPa and leaves at 320°C. The steam-cycle condenser operates at 20 kPa, and the isentropic efficiency of the steam turbine is 90 percent. Determine the mass flow rate of air through the air compressor required for this system to produce 100 MW of power. Use constant specific heats for air at room temperature.
Want to see the full answer?
Check out a sample textbook solutionChapter 10 Solutions
Thermodynamics: An Engineering Approach
Additional Engineering Textbook Solutions
Heating Ventilating and Air Conditioning: Analysis and Design
Applied Statics and Strength of Materials (6th Edition)
Fundamentals of Heat and Mass Transfer
Vector Mechanics for Engineers: Statics, 11th Edition
Fundamentals Of Thermodynamics
Vector Mechanics for Engineers: Statics and Dynamics
- A Combined power plant consists of a gas turbine unit and a steam turbine unit. The exhaust gas from the open-cycle gas turbine is the supply gas to the steam generator of the steam turbine cycle at which additional fuel is burned in the gas. The pressure ratio for the gas turbine is 30 the air inlet temperature is 180C, and the maximum cycle temperature is 8000C. Combustion in the steam generator raises the gas temperature to 8000C and the gas leaves the generator to the chimney at 1100C. Steam is supplied to the steam turbine at 60 bar, 6500C, and the condenser pressure is 0.1 bar.The isentropic efficiencies of the air compressor, gas turbine, and steam turbine are 85%, 88%, and 87% respectively. Taking Cp = 1.11 Kj/kgK and adiabatic index= 1.33 for the combustion gases, and neglecting the effect of the mass flow rate of fuel, feed-pump work, and all pressure losses, calculate;a) The required flow rates of air and steam for a total output of 200 MW;b) The power output of each unit;c)…arrow_forwardConsider a steam power plant that operates on a reheat Rankine cycle and has a net power output of 80 MW. Steam enters the high-pressure turbine at 10 MPa and 500°C and the low-pressure turbine at 1 MPa and 500°C. Steam leaves the condenser as a saturated liquid at a pressure of 10 kPa. The isentropic efficiency of the turbine is 80%, and that of the pump is 95 %. Show the cycle on a T-s diagram with respect to saturation lines, and determine (a)the quality (or temperature, if superheated) of the steam at the turbine exit, (b)the thermal efficiency of the cycle, and (c)the mass flow rate of the steam.arrow_forwardA Combined power plant consists of a gas turbine unit and a steam turbine unit. The exhaust gas from the open-cycle gas turbine is the supply gas to the steam generator of the steam turbine cycle at which additional fuel is burned in the gas. The pressure ratio for the gas turbine is 16, the air inlet temperature is 180C, and the maximum cycle temperature is 8000C. Combustion in the steam generator raises the gas temperature to 8000C and the gas leaves the generator to the chimney at 1100C. Steam is supplied to the steam turbine at 60 bar, 6500C, and the condenser pressure is 0.1 bar. The isentropic efficiencies of the air compressor, gas turbine, and steam turbine are 85%, 88%, and 87% respectively. Taking Cp = 1.11 Kj/kgK and adiabatic index= 1.33 for the combustion gases, and neglecting the effect of the mass flow rate of fuel, feed-pump work, and all pressure losses, calculate; The required flow rates of air and steam for a total output of 200 MW; The power output of each unit;…arrow_forward
- A steam power plant operates on an ideal regenerative Rankine cycle with two open feedwater heaters. Steam enters the turbine at 10 MPa and 600C and exhaust to the condenser at 5 kPa. Steam is extracted from the turbine at 0.6 and 0.2 MPa. Water leaves both feedwater heaters as a saturated liquid. The mass flow rate of steam through the boiler is 22 kg/sec. Show the cycle on a T-s diagram, and determine (a) Total power requirement of the pump in Hp, (b) Turbine power output in MW, (c) the net power output of the power plant in MW, (d) mass of steam extracted for feedwater heating in kg/sec,arrow_forwardA gas-turbine power plant operates on the simple Brayton cycle between the pressure limits of 100 and 1600 kPa. The working fluid is air, which enters the compressor at 40C at a rate of 850 m3/min and leaves the turbine at 650C. Using variable specific heats for air and assuming a compressor isentropic efficiency of 85 percent and a turbine isentropic efficiency of 88 percent, determine (a) the net power output, (b) the back work ratio, and (c) the thermal efficiency.arrow_forwardA steam power plant operates on an ideal Rankine cycle with two stages of reheat and has a net power output of 75 MW. Steam enters all three stages of the turbine at 550C. The maximum pressure in the cycle is 10 MPa, and the minimum pressure is 30 kPa. Steam is reheated at 4 MPa the first time and at 2 MPa the second time. Show the cycle on a T-s diagram with respect to saturation lines, and determine (a) the thermal efficiency of the cycle, and (b) the mass flow rate of the steam.arrow_forward
- A steam power plant operates on an ideal regenerative Rankine cycle with two open feedwater heaters. Steam enters the turbine at 8 MPa and 550C and exhausts to the condenser at 10 kPa. Steam is extracted from the turbine at 0.6 and 0.2 MPa. Water leaves both feedwater heaters as a saturated liquid. The mass flow rate of steam through the boiler is 16 kg/s. Show the cycle on a T-s diagram, and determine (a) the net power output of the power plant and (b) the thermal efficiency of the cycle.arrow_forwardConsider a steam power plant that operates on the ideal reheat Rankine cycle. The plant maintains the boiler at 5400 kPa, the reheat section 1100 kPa, and the condenser at 10 kPa. The mixture quality at the exit of both turbines is 94 %. Determine the following values. (1) The specific enthalpy at the exit of the high-pressure turbine. (2) The specific entropy at the exit of the high-pressure turbine. (3) The temperature at the inlet of the high-pressure turbine. (4) The temperature at the inlet of the low-pressure turbine. (5) The thermal efficiency of the cycle.arrow_forwardA steam power plant operating on a simple ideal Rankine cycle maintains the boiler at 6000 kPa, the turbine inlet at 600C, and the condenser at 50 kPa. Compare the thermal efficiency of this cycle when it is operated so that the liquid enters the pump as a saturated liquid against that when the liquid enters the pump 11.3C cooler than a saturated liquid at the condenser pressure.arrow_forward
- 1. What is the Isentropic Work of the Steam using the Ideal Rankine Cycle when the system is set at 400 kPaa Boiler Pressure and 105 kPaa Condenser Pressure when the system is generating power at 9,500 seconds? 2. With the Turbine work output, what is the Isentropic efficiency of the Turbine from the above settings?arrow_forwardConsider a steam power plant operating on the ideal Rankine cycle. Steam enters the turbine at 3 MPa and 623 K and is condensed in the condenser at a pressure of 10 kPa. Determine (i) the thermal efficiency of this power plant, (ii) the thermal efficiency if steam is superheated to 873 K instead of 623 K, and (iii) the thermal efficiency if the boiler pressure is raised to 15 MPa while the turbine inlet temperature is maintained at 873 K.arrow_forwardA steam power plant operating on an intermediate steam Rankine cycle has an open feedwater heater. The enthalpy of the steam at the turbine inlet is 3208 kJ/kg, the enthalpy at the split point is 2648 kJ/kg, and the enthalpy at the turbine exit is 2158 kJ/kg. The net power of the power plant is 100 MW, and the mass ratio of the steam leaving the turbine in the intermediate steam intake is 0.244. What is the mass flow rate of steam at the turbine inlet if the pump work is ignored?arrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY