A three-phase system is constructed from a balanced Y-connected source operating at 50 Hz and having a line voltage of 210 V, and each phase of the balanced load draws 130 W at a leading power factor of 0.75. (a) Calculate the line current and the total power supplied to the load. (b) If a purely resistive load of 1 Ω is connected in parallel with each existing load, calculate the new line current and total power supplied to the load. (c) Verify your answers using appropriate simulations.
Want to see the full answer?
Check out a sample textbook solutionChapter 12 Solutions
Loose Leaf for Engineering Circuit Analysis Format: Loose-leaf
Additional Engineering Textbook Solutions
Programmable Logic Controllers
Electric machinery fundamentals
Electric Circuits. (11th Edition)
Basic Engineering Circuit Analysis
Introductory Circuit Analysis (13th Edition)
Electric Circuits (10th Edition)
- Don't copy paste from chegg load is supplied through a 275kV link of total reactance 50V from an infinite busbar at 275 kV. Plot the receiving-end voltage against power graph for a constant load power factor of 0.95 lagging. The system resistance may be neglected. Describe two methods of controlling voltage in a power system. a. Show how the scalar voltage difference between two nodes in a network is given approximately by: DV ¼ RP þ XQ V Each phase of a 50km, 132km overhead line has a series resistance of 0.156 V/km and an inductive reactance of 0.4125V/km. At the receiving end the voltage is 132 kV with a load of 100MVA at a power factor of 0.9 lagging. Calculate the magnitude of the sending-end voltage. b. Calculate also the approximate angular difference between the sendingend and receiving-end voltages.arrow_forwardDefine the scenario when the real power flows through a transmission line is zero. For the same scenario consider the sender voltage is 50KV and receiver voltage is 60 KVand currents flows through the system is 150 amps. Find the real and reactive power of the transmission line. Draw the power flow diagram and define the power flow direction.arrow_forwardA 3-phase, 50-Hz overhead transmission line 100 km long has the following constants : Resistance/km/phase = 0.1 Ω Inductive reactance/km/phase = 0·2 Ω Capacitive susceptance/km/phase = 0·04 × 10− 4 siemens Determine sending end voltage when supplying a balanced load of 10,000 kW at 66 kV, p.f. 0·8 lagging. Use nominal T method . Select one: a. 330 kV b. 52 kV c. None of the above d. 69.5 kVarrow_forward
- A 530 kV, three phase transmission line with a 350 km length. The series impedance Z =(0.11+j0.72) Ω/ph/km and shunt admittance y = (j73 x e(-7)) S/ph/km. Evaluate the equivalent π-model and T-model parameters.arrow_forwardA 3-phase, 50 Hz, 20 km long overhead line supplies 1000 kW at 11kV, 0.8 p.f. lagging. The line resistance is 0.03 & per phase per km and line inductance is 0.7 mH per phase per km. Calculate the sending end voltage, voltage regulation and efficiency of transmission.arrow_forward9. A 3-phase, 230-V feeder has three different loads drawing maximum demands of 34 A, 48 A, and 50 A. if the diversity factor of the feeder is 1.2, find the maximum KVA demand.arrow_forward
- A 3-phase Y-connected source (400V) supplies a 3-phase Y-connected load (3xZload = 27 + 9.0 ohm) via a non-ideal, three-core cable. No neutral line is available. Each conductor of the cable has an impedance Zcable = 80 + 2.1 mOhm a. Measure the phase shift angle between line voltage and phase voltage. b. Because of a fault, one of the three load impedances changes to half its original value. What happens to the phase voltages at the load.arrow_forward1. A balanced, three-phase, 900V system is supplying a balanced load connected in delta. A three-phase wattmeter (measuring total three-phase power) is connected to the supply and an ammeter is connected to one of the supply phases. Each load consists of a resistance in parallel with an inductive reactance. a. If the wattmeter reads 14.1 kW, what is the resistance of each load? b. If the ammeter reads 10 A What is the impedance (Z) of each load? c. What is the reactance (X)? d. If this load was instead connected in star, what would the new readings be? (P and I).( need only handwritten solution .otherwise downvote.)arrow_forwarda) A balanced three-phase delta-connected overhead line has constants A = 0.9/10°, B = 50/64° Ω . The receiving end line voltage is held at 330kV. The line is to transmit 1000MWat a power factor of 0.9 lagging at the receiving end. Determine the following: i) Receiving end current ii) Sending end voltage b) If the line is now to transmit 900 MW at a leading power factor of 0.8 at the receiving end determine the following: i) Receiving end current ii) Sending end current PLEASE Comment on your answers to a) and b) PLEASE I NEED CORRECT SOLUTION. THANK YOU.arrow_forward
- A 230 V, three phase, 4 wire balance system supplies power to group of lamp of loads. If the line currents are respectively 60 A, 86 A and 40 A respectively, solve for the current in the neutral wires. Assume the power factor of the lamps to be unity.arrow_forwardThe time-domain expressions for three line-to-neutral voltages at the terminals of a Y-connected load are v AN = 169.71 cos (ωt+ 26 ∘ ) V, v BN = 169.71 cos (ωt− 94 ∘ ) V, v CN = 169.71 cos (ωt− 94 ∘ ) V, What are the time-domain expressions for the three line-to-line voltages vAB, vBC, and vCA?arrow_forwardA radial transmission line system can be represented by a generating source connected to a three-phase transformer – (11kV/132kV, 50MVA, 10 % reactance) to which an overhead transmission line (j100 Ω) is connected. Connected to the other end of the transmission line is another three-phase transformer (132kV/33kV,50MVA, 12% reactance). This three-phase transformer located at a 33kV substation supplies a load of 30MW at a power factor of 0.8 lagging. The voltage level of the substation is to be maintained at 30kV. Use a base of 100MVA and 33kV . Use the above information to answer Q12 – Q16 12. Calculate the per unit value of reactance of the sending end transformer. a) 0.20 b) 0.25 c) 0.30 d) 0.343 e) none 13. Calculate the per unit value of reactance of the receiving end transformer. a) 0.32 b) 0.24 c) 0.41…arrow_forward
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,