Fluid Mechanics: Fundamentals and Applications
4th Edition
ISBN: 9781259696534
Author: Yunus A. Cengel Dr., John M. Cimbala
Publisher: McGraw-Hill Education
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 14, Problem 23EP
To determine
(a)
The units of the coefficient
To determine
(b)
The expression for the free discharge
To determine
(c)
The operating capacity.
The operating point capacity of the pump.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Three pumps are connected in series. According to pump performance curves, the free delivery of each pump is as follows: Pump 1: 1600 L/min Pump 2: 2200 L/min Pump 3: 2800 L/min If the flow rate for this pump system is 2500 L/min, which pump(s) should be shut off? (a) Pump 1 (b) Pump 2 (c) Pump 3 (d) Pumps 1 and 2 (e) Pumps 2 and 3
1) Interpret solar power in the context of environmental impact.2. What is the rigid dichotomy between windmill and diesel-driven pumps?3. For a normal windmill-driven pump at 3 m/s wind speed, the yield at a 10 m Head is typically 0.12 liters/s per m2 of rotor area, value windmills in the context of yield.
Two pumps (Pump A and B) have performance curves which can be approximated by the following equations:
H_A = 340 - (1.2(Q^2)), in feet
H_B = 360 - (2.5(Q^2)), in feet
where Q is in ft^3/s.
If pumps A and B were to operate in parallel as depicted in the figure below, at what head (in ft.) should either pump be operated?
Chapter 14 Solutions
Fluid Mechanics: Fundamentals and Applications
Ch. 14 - What is the more common term for an...Ch. 14 - What the primary differences between fans,...Ch. 14 - List at least two common examples of fans, of...Ch. 14 - Discuss the primary difference between a porn...Ch. 14 - Explain why there is an “extra” term in the...Ch. 14 - For a turbine, discuss the difference between...Ch. 14 - Prob. 7CPCh. 14 - Prob. 8PCh. 14 - Prob. 9PCh. 14 - Prob. 10CP
Ch. 14 - There are three main categories of dynamic pumps....Ch. 14 - For each statement about cow cetrifugal the...Ch. 14 - Prob. 13CPCh. 14 - Consider flow through a water pump. For each...Ch. 14 - Write the equation that defines actual (available)...Ch. 14 - Consider a typical centrifugal liquid pump. For...Ch. 14 - Prob. 17CPCh. 14 - Consider steady, incompressible flow through two...Ch. 14 - Prob. 19CPCh. 14 - Prob. 20PCh. 14 - Suppose the pump of Fig. P1 4-19C is situated...Ch. 14 - Prob. 22PCh. 14 - Prob. 23EPCh. 14 - Consider the flow system sketched in Fig. PI 4-24....Ch. 14 - Prob. 25PCh. 14 - Repeat Prob. 14-25, but with a rough pipe-pipe...Ch. 14 - Consider the piping system of Fig. P14—24. with...Ch. 14 - The performance data for a centrifugal water pump...Ch. 14 - For the centrifugal water pump of Prob. 14-29,...Ch. 14 - Suppose the pump of Probs. 14-29 and 14-30 is used...Ch. 14 - Suppose you are looking into purchasing a water...Ch. 14 - The performance data of a water pump follow the...Ch. 14 - For the application at hand, the flow rate of...Ch. 14 - A water pump is used to pump water from one large...Ch. 14 - For the pump and piping system of Prob. 14-35E,...Ch. 14 - A water pump is used to pump water from one large...Ch. 14 - Suppose that the free surface of the inlet...Ch. 14 - Calculate the volume flow rate between the...Ch. 14 - Comparing the results of Probs. 14-39 and 14-43,...Ch. 14 - Prob. 45PCh. 14 - The performance data for a centrifugal water pump...Ch. 14 - Transform each column of the pump performance data...Ch. 14 - 14-51 A local ventilation system (a hood and duct...Ch. 14 - Prob. 52PCh. 14 - Repeat Prob. 14-51, ignoring all minor losses. How...Ch. 14 - Suppose the one- way of Fig. P14-51 malfunctions...Ch. 14 - A local ventilation system (a hood and duct...Ch. 14 - For the duct system and fan of Prob. 14-55E,...Ch. 14 - Repeat Prob. 14-55E, ignoring all minor losses....Ch. 14 - A self-priming centrifugal pump is used to pump...Ch. 14 - Repeat Prob. 14-60. but at a water temperature of...Ch. 14 - Repeat Prob. 14-60, but with the pipe diameter...Ch. 14 - Prob. 63EPCh. 14 - Prob. 64EPCh. 14 - Prob. 66PCh. 14 - Prob. 67PCh. 14 - Prob. 68PCh. 14 - Prob. 69PCh. 14 - Two water pumps are arranged in Series. The...Ch. 14 - The same two water pumps of Prob. 14-70 are...Ch. 14 - Prob. 72CPCh. 14 - Name and briefly describe the differences between...Ch. 14 - Discuss the meaning of reverse swirl in reaction...Ch. 14 - Prob. 75CPCh. 14 - Prob. 76CPCh. 14 - Prob. 77PCh. 14 - Prob. 78PCh. 14 - Prob. 79PCh. 14 - Prob. 80PCh. 14 - Wind ( =1.204kg/m3 ) blows through a HAWT wind...Ch. 14 - Prob. 82PCh. 14 - Prob. 84CPCh. 14 - A Francis radial-flow hydroturbine has the...Ch. 14 - Prob. 87PCh. 14 - Prob. 88PCh. 14 - Prob. 89PCh. 14 - Prob. 90CPCh. 14 - Prob. 91CPCh. 14 - Discuss which dimensionless pump performance...Ch. 14 - Prob. 93CPCh. 14 - Prob. 94PCh. 14 - Prob. 95PCh. 14 - Prob. 96PCh. 14 - Prob. 97PCh. 14 - Prob. 98PCh. 14 - Prob. 99PCh. 14 - Prob. 100EPCh. 14 - Prob. 101PCh. 14 - Calculate the pump specific speed of the pump of...Ch. 14 - Prob. 103PCh. 14 - Prob. 104PCh. 14 - Prob. 105PCh. 14 - Prob. 106PCh. 14 - Prob. 107EPCh. 14 - Prob. 108PCh. 14 - Prob. 109PCh. 14 - Prob. 110PCh. 14 - Prove that the model turbine (Prob. 14-109) and...Ch. 14 - Prob. 112PCh. 14 - Prob. 113PCh. 14 - Prob. 114PCh. 14 - Prob. 115CPCh. 14 - Prob. 116CPCh. 14 - Prob. 117CPCh. 14 - Prob. 118PCh. 14 - For two dynamically similar pumps, manipulate the...Ch. 14 - Prob. 120PCh. 14 - Prob. 121PCh. 14 - Prob. 122PCh. 14 - Calculate and compare the turbine specific speed...Ch. 14 - Prob. 124PCh. 14 - Prob. 125PCh. 14 - Prob. 126PCh. 14 - Prob. 127PCh. 14 - Prob. 128PCh. 14 - Prob. 129PCh. 14 - Prob. 130PCh. 14 - Prob. 131PCh. 14 - Prob. 132PCh. 14 - Prob. 133PCh. 14 - Prob. 134PCh. 14 - Prob. 135PCh. 14 - A two-lobe rotary positive-displacement pump moves...Ch. 14 - Prob. 137PCh. 14 - Prob. 138PCh. 14 - Prob. 139PCh. 14 - Prob. 140PCh. 14 - Which choice is correct for the comparison of the...Ch. 14 - Prob. 142PCh. 14 - In a hydroelectric power plant, water flows...Ch. 14 - Prob. 144PCh. 14 - Prob. 145PCh. 14 - Prob. 146PCh. 14 - Prob. 147PCh. 14 - Prob. 148PCh. 14 - Prob. 149PCh. 14 - Prob. 150PCh. 14 - Prob. 151P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- For each statement, choose whether the statement is true or false, and discuss your answer briefly: (a) If the rpm of a pump is doubled, all else staying the same, the capacity of the pump goes up by a factor of about 2. (b) If the rpm of a pump is doubled, all else staying the same, the net head of the pump goes up by a factor of about 2. (c) If the rpm of a pump is doubled, all else staying the same, the required shaft power goes up by a factor of about 4. (d) If the rpm of a turbine is doubled, all else staying the same, the output shaft power of the turbine goes up by a factor of about 8.arrow_forwardThe performance data of a water pump follow the curve fit Havailable = H0 = aV^2, where the pump’s shut off head H0=5.30 m, coefficient a =0.0453 m/(Lpm)^2, the units of pump head H are meters, and the units of V. are liters per minute (Lpm). The pump is used to pump water from one large reservoir to another large reservoir at a higher elevation. The free surfaces of both reservoirs are exposed to atmospheric pressure. The system curve simplifies to Hrequired =(z2- z1) + bV ^2, where elevation difference z2 =-z1 = 3.52 m,and coefficient b =0.0261 m(Lpm)^2. Calculate the operating point of the pump.arrow_forwardIn the pump performance curve, the point at which the net head is zero is called (a) Best efficiency point (b) Free delivery (c) Shutoff head (d) Operating point (e) Duty pointarrow_forward
- 1Two water pumps are arranged in series. The performance data for both pumps follow the parabolic curve fit Havailable =H0 =aV ^2. For pump 1, H0 =5.30 m and coefficient a =0.0438 m/Lpm^2; for pump 2, H0 =8.70 m and coefficient a =0.0347 m/Lpm^2. In either case, the units ofnet pump head H are m, and the units of capacity V are Lpm.Calculate the combined shutoff head. Complete Answer, thank youarrow_forwardPAY ATTENTION TO THE QUESTION : What is the resulting flow rate in the system if three pumps are used in parallel? (a) 0.483 m^3/s (b) 0.364 m^3/s (c) 0.333 m^3/s (d) 0.563 m^3/s 1. The Head -flowrate curve for a centrifugal pump is given by: HP = 28 -30Q2 Where, HP is in meter and Q is in m3/s . This pump is used to pump water for a system with the following (H-Q) curve: HS = 8 + 150Q2 Where, HS is in meter and Q is in m3/s . IT SAYS : if theee pumps are used in parallel PAY ATTENTION Multiple choice choose correct answerarrow_forwardThree pumps are connected in parallel. According to pump performance curves, the shutoff head of each pump is as follows: Pump 1: 7 m Pump 2: 10 m Pump 3: 15 m If the net head for this pump system is 9 m, which pump(s) should be shut off? (a) Pump 1 (b) Pump 2 (c) Pump 3 (d) Pumps 1 and 2 (e) Pumps 2 and 3arrow_forward
- A pump is designed to deliver 9500 L/min of water at a required head of 8 m. The pump shaft rotates at 1100 rpm. The pump specific speed in nondimensional form is (a) 0.277 (b) 0.515 (c) 1.17 (d ) 1.42 (e) 1.88arrow_forwardA pump has a characteristic curve described by the equation: hp = 15 - 0.2 x Q2 What is the pump characteristic curve for: (a) a system having three of these pumps in series; and (b) a system having three of these pumps in parallel? Sketch the pump characteristics curve for each case.arrow_forwardThe Head -flowrate curve for a centrifugal pump is given by: HP = 28 -30Q2 Where, HP is in meter and Q is in m3/s . This pump is used to pump water for a system with the following (H-Q) curve: HS = 8 + 150Q2 Where, HS is in meter and Q is in m3/s . What is the resulting flow rate in the system if three pumps are used in series? (a) 0.56 m^3/s (b) 0.48 m^3/s (c) 0.33 m^3/s (d) 0.36 m^3/s HINT: what is the resulting Flow-rate in the system if three pumps are used in series ? Choose correct option abovearrow_forward
- 1.The engine has a given capacity of 60kw, calculate the power requirement in a hydraulic system tool , to know that the engine is capable to support the hydraulic system if a pump delivers 110 liters per minute and the pressure is 227bar.2.If the area of A1 = 0.05 m˄2 and the area of A2 = 1.5 m˄2 , external input force F1 = 50 N, then the external output force F2 ?arrow_forwardA pump with an impeller diameter of 0.02 m, an impeller speed of 58.3 rpm, a * total capacity of 12 L/s, an available head of 70 m, and a brake power of 12 kW is used to pump water. Determine the capacity of a homologous pump with twice the impeller diameter and operating at half the speed. Choices: A.60L/S B.36 L/S C.48 L/S D.72L/Sarrow_forwardIn the turbomachinery industry, capacity refers to (a) Power (b) Mass flow rate (c) Volume flow rate (d) Net head (e) Energy grade linearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
Fluid Mechanics - Viscosity and Shear Strain Rate in 9 Minutes!; Author: Less Boring Lectures;https://www.youtube.com/watch?v=_0aaRDAdPTY;License: Standard youtube license