Fluid Mechanics: Fundamentals and Applications
4th Edition
ISBN: 9781259696534
Author: Yunus A. Cengel Dr., John M. Cimbala
Publisher: McGraw-Hill Education
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 14, Problem 34P
For the application at hand, the flow rate of Prob. 14-33 is not adequate. At least 9 Lpm is required. Repeat Prob. 13-33 for a more powerful pump the H0= 8.13 m and a = 0.0297 m /(Lpm)2. Calculate the percentage improvement m flow rate compared to the original pump. Is this pump able to deliver the required flow rate?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The S-shaped head-versus-flow curve in Fig. occursin some axial-flow pumps. Explain how a fairly flat systemloss curve might cause instabilities in the operation of thepump. How might we avoid instability?
A Francis turbine is to be designed to produce 27 MW at a shaft speed of 90rev/minunder an effective head of 27.8 m. Assuming that the optimum hydraulic efficiency is 90percent and the runner tip speed to jet speed ratio is 0.75, determine:(1) the power specific speed;(2) the volume flow rate;(3) the impeller diameter and blade tip speed.
choose the correct answer
Q1A- Using water jet forces to operate turbines in hydropower plant consider application of: *
a) Bernoulli’s equation
b) Darcy-Weisbach Equation
c) Manning equation
d) Momentum equation
E-none of all above
B-The main difference between the flow in pipes and the flow in open channels is *
a) Existing the head loss
b) Existing the free surface
c) Existing the pressure drop
d) None of all above
Chapter 14 Solutions
Fluid Mechanics: Fundamentals and Applications
Ch. 14 - What is the more common term for an...Ch. 14 - What the primary differences between fans,...Ch. 14 - List at least two common examples of fans, of...Ch. 14 - Discuss the primary difference between a porn...Ch. 14 - Explain why there is an “extra” term in the...Ch. 14 - For a turbine, discuss the difference between...Ch. 14 - Prob. 7CPCh. 14 - Prob. 8PCh. 14 - Prob. 9PCh. 14 - Prob. 10CP
Ch. 14 - There are three main categories of dynamic pumps....Ch. 14 - For each statement about cow cetrifugal the...Ch. 14 - Prob. 13CPCh. 14 - Consider flow through a water pump. For each...Ch. 14 - Write the equation that defines actual (available)...Ch. 14 - Consider a typical centrifugal liquid pump. For...Ch. 14 - Prob. 17CPCh. 14 - Consider steady, incompressible flow through two...Ch. 14 - Prob. 19CPCh. 14 - Prob. 20PCh. 14 - Suppose the pump of Fig. P1 4-19C is situated...Ch. 14 - Prob. 22PCh. 14 - Prob. 23EPCh. 14 - Consider the flow system sketched in Fig. PI 4-24....Ch. 14 - Prob. 25PCh. 14 - Repeat Prob. 14-25, but with a rough pipe-pipe...Ch. 14 - Consider the piping system of Fig. P14—24. with...Ch. 14 - The performance data for a centrifugal water pump...Ch. 14 - For the centrifugal water pump of Prob. 14-29,...Ch. 14 - Suppose the pump of Probs. 14-29 and 14-30 is used...Ch. 14 - Suppose you are looking into purchasing a water...Ch. 14 - The performance data of a water pump follow the...Ch. 14 - For the application at hand, the flow rate of...Ch. 14 - A water pump is used to pump water from one large...Ch. 14 - For the pump and piping system of Prob. 14-35E,...Ch. 14 - A water pump is used to pump water from one large...Ch. 14 - Suppose that the free surface of the inlet...Ch. 14 - Calculate the volume flow rate between the...Ch. 14 - Comparing the results of Probs. 14-39 and 14-43,...Ch. 14 - Prob. 45PCh. 14 - The performance data for a centrifugal water pump...Ch. 14 - Transform each column of the pump performance data...Ch. 14 - 14-51 A local ventilation system (a hood and duct...Ch. 14 - Prob. 52PCh. 14 - Repeat Prob. 14-51, ignoring all minor losses. How...Ch. 14 - Suppose the one- way of Fig. P14-51 malfunctions...Ch. 14 - A local ventilation system (a hood and duct...Ch. 14 - For the duct system and fan of Prob. 14-55E,...Ch. 14 - Repeat Prob. 14-55E, ignoring all minor losses....Ch. 14 - A self-priming centrifugal pump is used to pump...Ch. 14 - Repeat Prob. 14-60. but at a water temperature of...Ch. 14 - Repeat Prob. 14-60, but with the pipe diameter...Ch. 14 - Prob. 63EPCh. 14 - Prob. 64EPCh. 14 - Prob. 66PCh. 14 - Prob. 67PCh. 14 - Prob. 68PCh. 14 - Prob. 69PCh. 14 - Two water pumps are arranged in Series. The...Ch. 14 - The same two water pumps of Prob. 14-70 are...Ch. 14 - Prob. 72CPCh. 14 - Name and briefly describe the differences between...Ch. 14 - Discuss the meaning of reverse swirl in reaction...Ch. 14 - Prob. 75CPCh. 14 - Prob. 76CPCh. 14 - Prob. 77PCh. 14 - Prob. 78PCh. 14 - Prob. 79PCh. 14 - Prob. 80PCh. 14 - Wind ( =1.204kg/m3 ) blows through a HAWT wind...Ch. 14 - Prob. 82PCh. 14 - Prob. 84CPCh. 14 - A Francis radial-flow hydroturbine has the...Ch. 14 - Prob. 87PCh. 14 - Prob. 88PCh. 14 - Prob. 89PCh. 14 - Prob. 90CPCh. 14 - Prob. 91CPCh. 14 - Discuss which dimensionless pump performance...Ch. 14 - Prob. 93CPCh. 14 - Prob. 94PCh. 14 - Prob. 95PCh. 14 - Prob. 96PCh. 14 - Prob. 97PCh. 14 - Prob. 98PCh. 14 - Prob. 99PCh. 14 - Prob. 100EPCh. 14 - Prob. 101PCh. 14 - Calculate the pump specific speed of the pump of...Ch. 14 - Prob. 103PCh. 14 - Prob. 104PCh. 14 - Prob. 105PCh. 14 - Prob. 106PCh. 14 - Prob. 107EPCh. 14 - Prob. 108PCh. 14 - Prob. 109PCh. 14 - Prob. 110PCh. 14 - Prove that the model turbine (Prob. 14-109) and...Ch. 14 - Prob. 112PCh. 14 - Prob. 113PCh. 14 - Prob. 114PCh. 14 - Prob. 115CPCh. 14 - Prob. 116CPCh. 14 - Prob. 117CPCh. 14 - Prob. 118PCh. 14 - For two dynamically similar pumps, manipulate the...Ch. 14 - Prob. 120PCh. 14 - Prob. 121PCh. 14 - Prob. 122PCh. 14 - Calculate and compare the turbine specific speed...Ch. 14 - Prob. 124PCh. 14 - Prob. 125PCh. 14 - Prob. 126PCh. 14 - Prob. 127PCh. 14 - Prob. 128PCh. 14 - Prob. 129PCh. 14 - Prob. 130PCh. 14 - Prob. 131PCh. 14 - Prob. 132PCh. 14 - Prob. 133PCh. 14 - Prob. 134PCh. 14 - Prob. 135PCh. 14 - A two-lobe rotary positive-displacement pump moves...Ch. 14 - Prob. 137PCh. 14 - Prob. 138PCh. 14 - Prob. 139PCh. 14 - Prob. 140PCh. 14 - Which choice is correct for the comparison of the...Ch. 14 - Prob. 142PCh. 14 - In a hydroelectric power plant, water flows...Ch. 14 - Prob. 144PCh. 14 - Prob. 145PCh. 14 - Prob. 146PCh. 14 - Prob. 147PCh. 14 - Prob. 148PCh. 14 - Prob. 149PCh. 14 - Prob. 150PCh. 14 - Prob. 151P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Using the specific rotation speed, what would be the best turbine option for a waterfallof 120m and a flow of 6m³/s, working with a 12-pole generator? And what would be the nqa for thissituation?ALTERNATIVESa) Francis Turbine Normal, nqa= 121.88.b) Kaplan turbine, nqa= 7312.89.c) Slow Francis Turbine, nqa=98.15.d) Deriaz Turbine, nqa= 290.5.e) Pelton turbine, nqa= 29.05.arrow_forwardAssume a horizontal shaft handling water at 65 deg C (Pv=2.503 KPa, Density=980.5 m3/kg). The suction nozzle is 1.64 m below the pump centerline and the pressure gauge reading at this point is 221Kpag. Determine the NPSHa if the head loss is 0.94 m.arrow_forwardWhat is the pressure drop in the turbine? Answer: 1176.91 kPa (replace “turbine pressure drop” for “pump pressure increase”)arrow_forward
- The design of a new dam reveals that a water head of 10 meter and water flow rate of 100 cubic meter per second (m3/s) can be supplied for electricity generation. What kind of turbines would you recommend for the electric power generation?arrow_forwardWhich choice is correct for the comparison of the operation of impulse and reaction turbines? (a) Impulse: Higher flow rate (b) Impulse: Higher head (c) Reaction: Higher head (d) Reaction: Smaller flow rate (e) None of thesearrow_forwardWater at 20°C is to be pumped through 2000 ft of pipe fromreservoir 1 to 2 at a rate of 3 ft3/s, as shown in Fig. P6.62.If the pipe is cast iron of diameter 6 in and the pump is75 percent efficient, what horsepower pump is needed?arrow_forward
- A Francis turbine develops 3 MW under a head of 50 m at an overall efficiency of 88%. The diameterof the runner at the inlet is 80 cm and runner rotates with 300 rpm. If hydraulic efficiency of the turbine is90% and runner height at the inlet is 10cm, calculate (a) guide vane angle at inlet (b) blade angle at inletand (c) degree of reaction of the turbine.arrow_forwardExplain why some pump performance curves may lead tounstable operating conditions.arrow_forwardQuestion 2) The centrifugal pump in the figure is in his preference Passing water at 25°C from the tank through the 1.22 m exchange store pumping. Inner diameter of the suction channel is 101.6 mm, in total it is 0.0306 and its length is 3.2 m. It the local coefficients of the user in the pipe are 7.4. If the pump works at a flow rate of 109 m3/h ENPY=1.52 is m. Does the pump work without cavitation at this flow? Show the calculation. For water, p=997 kg/m3 and Pb=3.169 kPa. Piping system at the entrance (Suction pipe) pump 22 Patm=101.3 kPa and 0.2=1.05. vanarrow_forward
- A turbine of 9000 B.H.P. is working under a head of 25 mand runs at 100 R.P.M.- What will be the type of turbine ? Whatshould be its speed and power, when it is working under a head of16 m?arrow_forwardQ:/ Discuss the relation betwveen the head pressure and flow rate for the benefits of connecting the pumps in parallel ?arrow_forwardA multi stage pump is required to deliver of 2 l/s water against a maximum discharge head of 240 m. The diameter of radial bladed impeller should not be more than 15 cm. Assume a speed of 2800 rpm. Determine the impeller diameter, and power. Overall efficiency is 0.7.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Automotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Intro to Compressible Flows — Lesson 1; Author: Ansys Learning;https://www.youtube.com/watch?v=OgR6j8TzA5Y;License: Standard Youtube License