Chapter 3, Problem 3.3QAP
Interpretation Introduction
Interpretation:
Open loop gain of a comparator needed to keep the absolute value of the difference voltage within the given range is to be calculated.
Concept introduction:
The open loop gain of a comparator can be expressed as a ratio of output voltage to its input voltage
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The molar absorptivity for aqueous solutions of phenol at 211 nm is 6.17 × 103 L cm-1 mol-1.
Calculate the permissible range of phenol concentrations if the transmittance is to be less than 85% and greater than 7% when the measurements are made in 1.00-cm cells.
Calculate the effect that increasing the overpotential from 0.50 V to 0.60 V has on the current density in the electrolysis of 1.0 m NaOH(aq), which is 1.22 mA cm−2 at 0.50 V and 25 °C. Take α = 0.50.
A Dubosq colorimeter consists of a cell of fixed path length and a cell of variable path length. By adjusting the length of the latter until the transmission through the two cells is the same. the concentration of the second solution can be inferred from that of the former. Suppose that a plantdye of concentration 25 μg dm-3 is added to the fixed cell. the length of which is 1.55 em. Then a solution of the same dye. but of unknown concentration. is added to the second cel l. It is found that the same t ransmittance is obtained when the length of the second cel l is adjusted to 1.18 em. What is the concentration of the second solution?
Chapter 3 Solutions
Principles of Instrumental Analysis
Ch. 3 - Prob. 3.1QAPCh. 3 - Prob. 3.2QAPCh. 3 - Prob. 3.3QAPCh. 3 - Prob. 3.4QAPCh. 3 - Prob. 3.5QAPCh. 3 - Prob. 3.6QAPCh. 3 - Prob. 3.7QAPCh. 3 - Prob. 3.8QAPCh. 3 - Prob. 3.9QAPCh. 3 - Prob. 3.10QAP
Ch. 3 - Prob. 3.11QAPCh. 3 - Prob. 3.12QAPCh. 3 - Prob. 3.13QAPCh. 3 - Prob. 3.14QAPCh. 3 - Prob. 3.15QAPCh. 3 - Prob. 3.16QAPCh. 3 - Prob. 3.17QAPCh. 3 - Prob. 3.18QAPCh. 3 - Prob. 3.19QAPCh. 3 - Prob. 3.20QAPCh. 3 - Prob. 3.21QAPCh. 3 - Prob. 3.22QAPCh. 3 - Prob. 3.23QAPCh. 3 - Prob. 3.24QAPCh. 3 - Prob. 3.25QAP
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- Describe the difference between power-compensated, heat-flux, and modulated DSC instruments.arrow_forwardUse the data in Table 19D.1 for the exchange-current density and transfer coefficient for the reaction Fe3+ + e− → Fe2+ on platinum at 25 °C to identify the current density needed to obtain an overpotential of 0.30 V as calculated (i) by using the Butler–Volmer equation, and (ii) by assuming that the current is entirely anodic. Comment on the validity of the latter assumption.arrow_forwardThe absorbances of solutions containing K2CrO4 in 0.05 M KOH were measured in a 1.0-cm cell of 375 nm. The following results were obtained: Calculate the linear equation of the calibration curve.arrow_forward
- Calculate the specific absorbance ratio (SAR), where A620 = 0.136 and A280 = 1.392. Enter your result with 3 decimal places.arrow_forwardWhat are the similarities between fluorescence detectors in HPLC and chemiluminescence detectors in HPLC?arrow_forwardThe classical dissociation constant of propionic acid, C2H5CO2H, is 1.34 x10-5 moldm-3 at 250C and the limiting molar conductivities at zero concentration of hydrogen and propionate ions are 349.8 and 35.8 ohm-1 cm2 mol-1 respectively. Calculation of the resistivity of 0.100 M solution of propionic acid.arrow_forward
- What is the purpose of waiting 1s after a voltage pulse before measuring current in sampled current voltammetry?arrow_forwardState the difference between transmittance, absorbance, and molar absorptivity. Which one is proportional to concentration?arrow_forwardA water sample was run through the colorimetric procedure for the analysis of nitrate, giving 65.0% transmittance. A sample containing 1.00 ppm nitrate run through the exactly the same/identical procedure gave 24.6% transmittance. What was the concentration of nitrate in the first sample?arrow_forward
- What are the basic differences between absorption & adsorption, and sorption?arrow_forwardThe logarithm of the molar absorptivity of acetone in ethanol is 2.75 to 366 nm. Calculate the range of acetone concentrations that can be worked on if The transmittance percentage must be greater than 10% and less than 90% %, measured in a cell with an optical pitch of 1.50 cm.arrow_forward