Consider a thin-walled, metallic tube of length
(a) What is the outlet temperature of the water if the tube surface temperature is maintained at 27°C?
(b) 1f a 0.5-mm-thick layer of insulation of
(c) If the outer surface of the insulation is no longer maintained al
Want to see the full answer?
Check out a sample textbook solutionChapter 8 Solutions
Fundamentals of Heat and Mass Transfer
Additional Engineering Textbook Solutions
Mechanics of Materials
Engineering Mechanics: Dynamics (14th Edition)
EBK FUNDAMENTALS OF THERMODYNAMICS, ENH
Applied Statics and Strength of Materials (6th Edition)
Machine Elements in Mechanical Design (6th Edition) (What's New in Trades & Technology)
Thermodynamics: An Engineering Approach
- Engine oil is heated by flowing through a circular tube of Diameter D= 50 mm, length L= 25, and whose surface is maintained at 150 Deg. C. If the flow rate and inlet temperature of the oil are 0.5 Kg/s and 20 Deg.C Use the following properties: p= 852 kg/m³, o-u/p-37.5 x10-6 m²/s, k=138x10-3 W/m.K, Pr = 490, C₂= 2131 J/kg.K. u= px 0= 0.032 kg/m.s m = 0.5 kg/s Engine Oil Tml = 20 C DIA = 0.05 m 9 Ts = 150 C L = 25 m Tmo? Based on the above information. 1. Find Rep 2. Based on the value of Rep, what type of flow do we have? 3. Determine the outlet mean temperature Tm.o, with the average heat transfer coefficient = 33.12 W/m^2.Karrow_forwardConsider a thick-walled steel pipe of inside and outside diameters D-20mm_and d =40mm and 10m length. The outer surface of the pipe is maintained at T_{s} = 90 C water entered at the rate of m =1kg/s and T mi =20 C.What is the outlet temperature of the water? What is the inner surface temperature of the pipe at the outlet? Neglect the natural convection. Steel: rho = 7830kg / (m ^ 3) k = 49W / m * K c_{p} = 550J / k * gKarrow_forwardA gas is cooled by circulating it in a turbulent regime through the interior of a circular duct with an internal diameter D; = 0.025 mm, whose internal wall remains constant at To,i = 310 K. The average temperature of the gas is Tm = 350 K, its density Pm = 1.01 kg/m³ and its thermal conductivity Am = 0.0297 W/(m K). The Reynolds number is equal to Rep = 28717, the Prandtl number Pr = 0.718 and the pressure drop per unit length, AP/L = 300 Pa/m. 3. What is the value of the mass flux? G = kg/(m's) 4. What is the value of the convection coefficient if the duct is very long? (D/L → 0) h = W/(m² K)arrow_forward
- Heat transfer Air flows through a smooth thin-walled rectangular duct of height, a= 0.3 m and width, b=1 m. The air is heated by the duct walls at a uniform heat flux of 250 W/m2 . At some location inside the duct, the mean velocity and temperature of air was measured to be um = 0.05 m/s and Tm = 350 K, respectively. (a) What is the hydraulic diameter of the duct? (b) What is the Reynolds number for the flow in the duct? (c) Is the flow laminar or turbulent? (d) Assuming fully developed flow, what is the heat transfer coefficient (h) at this location?arrow_forwardWater at 15°C (p = 999.1 kg/m3, cp = 4.18 kJ/kg.K and u = 1.138E-3 kg/m.s k = 0.631 W/m.°C) is flowing steadily in a 4.3-cm-diameter, 9.9- m-length horizontal pipe made of stainless steel at a rate of 1.9 kg/min, the outer surface is subjected, to a uniform heat flux of 6.2 kW/m". Assume fully developed flow. What is the pressure drop in the pipe "in Pascals"? Select one: А. 4.98 B. 5.62 С. 4.26 D. 3.53 O E. 6.26arrow_forwardHeated air at 1 atm and 100°F is to be transported in a 900-ft-long circular section plastic duct at a rate of 1.4 lb/s. I want to determine the head loss and pumping power at the three diameter values in the table below. Complete the table to help me choose a wise diameter. Why would a good design not only focus on minimizing the pumping power? Diameter Head loss, hi Pumping power, W Reynolds number, Re n.d. f n.d. (in) ft hp 8 12 16arrow_forward
- T0 2-Water is heated as it flows through a square duct with side a=2 cm and the mean velocity through each is U = 3.2 cm/s. Duct is heated electrically by 2000 W/m2 into the water. Assuming that the water properties can be evaluated at 50◦C and that the flow is thermally fully developed: (a) Verify that the flow is laminar. (b) Calculate heat transfer coefficient (c) the mean temperature difference between the wall and the water stream. (d) Calculate the rate of temperature increase along the channel, (e) calculate pressure drop per unit lengtharrow_forwardHot water, k=48 W/m. It flows at a speed of 1.4 m/s along the cast iron pipe at oC. The inner and outer diameters of the pipe are 3.0 and 3.5 cm, respectively. The pipe is located within 15 m of a basement with a temperature of 15 °C. If the temperature of the water drops from 70 oC to 67 oC while passing through the basement and the film heat transfer coefficient on the inner surface of the pipe is 400 W/m2. Calculate the convective heat transfer coefficient on the outer surface of the pipe and the heat to be transferred.arrow_forwardA liquid metal flows at a mass rate of 3 kg/s through a constant heat flux 5-cm-i.d tube in a nuclear reactor. The fluid at 473 K is to be heated with the tube wall 30 K above the fluid temperature. Determine the length of the tube required for a 1-K rise in bulk fluid temperature, using the following properties: p = 7.7 x 10^3 kg/m^3v = 8.0 x 10^-8 m^2/sCp = 130 J/(kg K)k = 12 W/mKPr = 0.011 Kaufman's correlation: Nu = 0,625.(Re.Pr)0,4arrow_forward
- Water flows inside the tube 45mm diameter and 3.5 meters long at a velocity 1m/s. Determine the heat transfer coefficient and the rate of heat transfer if the mean water temperature is 50 degree celsius and the tube wall is 70 degree celsius. kfor water is 0.68W/m degree celsius and the kinematic viscocity is 0.478x10^-6 m2/s and the Pr= 2.98. use the Dittus and Boelter equation to solve for Nu.arrow_forwarda] Steam at 280 oC, tube=26 W/m. It flows at a speed of 4.0 m/s along a pipe made of iron-steel material with a temperature of 0°C. The inner diameter of the iron-steel pipe is 6.0 cm and the outer diameter is 6.8 cm. In order to reduce the heat transfer, the iron-steel pipe is first covered with 2.0 cm thick glass wool (k = 0.38 W/m. oC), then with another 3.5 cm thick insulation material (k = 0.01 W/m. oC). The insulated iron-steel pipe is in the atmospheric environment where the temperature is 18 oC. The convective heat transfer coefficient on the outside atmospheric side of this pipe, where the steam flows, is 36 W/m2. oC, the film heat transfer coefficient on the steam side is 80 W/m2. Calculate the heat transferred per unit pipe length (W/m), since it is known to be °C. b] Calculate the thickness of the material when the pipe is sheathed externally with a material with a thermal conductivity of k=0.02 W/m.oC in order to reduce the heat to be transferred by 20% in the unit pipe…arrow_forwardHot water, k=48 W/m. It flows along the cast iron pipe, which is oC, at a speed of 1.4 m/s. The inner and outer diameter of the pipe are 3.0 and 3.5 cm, respectively. The pipe is located in a 15 m section of a basement floor with a temperature of 15 oC. If the water temperature drops from 70 OC to 67 OC when passing through the basement, and the film heat transfer coefficient on the inner surface of the pipe is 400 W/m2. If oC is, calculate the convective heat transfer coefficient on the outer surface of the pipe and the heat that will be transferred.arrow_forward
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning