Air at
(a) If the tube surface temperature at the exit is
(b) It the tube length of’ part (a) were reduced to
(c) If the flow rate of part (a) were increased by a factor of 10, would there be a difference in flow conditions at the lube exit? Would the value of the heat transfer coefficient at the tube exit be greater than, equal to, or smaller than the heat transfer coefficient for part (a)?
Want to see the full answer?
Check out a sample textbook solutionChapter 8 Solutions
Fundamentals of Heat and Mass Transfer
Additional Engineering Textbook Solutions
Introduction To Finite Element Analysis And Design
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Statics and Mechanics of Materials (5th Edition)
Engineering Mechanics: Dynamics (14th Edition)
Automotive Technology: Principles, Diagnosis, And Service (6th Edition) (halderman Automotive Series)
- You are provided a horizontal tube with one entrance and one exit. Air (Cp = 1.005 kJ/(kg-K)) is passing through the pipe and is assumed ideal. The inlet conditions are 102 psia, 101 degrees Fahrenheit and velocity 9feet/second. Determine the outlet velocity (ft/s) and outlet temperature (degrees Fahrenheit) if the exit conditions are 2.1 psia. Assume the process occurs under adiabatic conditionsarrow_forwardQ2. A concentric annulus tube has inner and outer diameters of 25 mm and 100 mm, respectively. Liquid water flows at a mass flow rate of 0.05 kg/s through the annulus with the inlet and outlet mean temperatures of 20°C and 80°C, respectively. The inner tube wall is maintained with a constant surface temperature of 120°C, while the outer tube surface is insulated. Determine the length of the concentric annulus tube. Assume flow is fully developed. T, Insulation Waterarrow_forwardQ=2000J Tout=? V(m/s) D=0.1m air Air at (3.050x10^2) K is entering in a circular pipe at 101325 Pa as shown in Figure. The velocity of the air at the pipe entrance is (1.50x10^0) m/s. The diameter of the pipe is 0.1m. Specific gas constant of air is 287 J/kg-K. Specific heat of air is 1000 J/kg-K. Find the outlet temperature if 2000 J of heat is added to the pipe. Answer should be in 'K' with three significant figures. Note: Your answer is assumed to be reduced to the highest power possible. Your Answer: x10 Answer DELLarrow_forward
- Pressurized water (pin = 10 bar, Tin =110◦C) enters the bottom of an L = 12m long vertical tube of diameter D = 110 mm at a mass flow rate of m =1.5kg/s . The tube is located inside a combustion chamber, resulting in heat transfer to the tube. Superheated steam exits the top of the tube at pout = 7 bar, Tout = 600◦C. Determine the change in the rate at which the following quantities enter and exit the tube: (a) the combined thermal and flow work, (b) the mechanical energy, and (c) the total energy of the water. Also, (d) determine the heat transfer rate, Q˙. Hint: Relevant properties may be obtained from a thermodynamics text.arrow_forwardQ=2000J Vout =? m (kg/s) D=0.1m air Air at (4.65x10^2) K flows out of a circular pipe at 101325 Pa as shown in Figure. The mass flowrate of the air at the pipe entrance is 0.0093 kg/s. The diameter of the pipe is 0.1m. Specific gas constant of air is 287 J/kg-K. Specific heat of air is 1000 J/kg-K. Find the outlet Velocity if 2000 J of heat is added to the pipe. Note: Your answer is assumed to be reduced to the highest power possible. Your Answer: x10 Answerarrow_forward4. An experimental test rig is used to examine two-phase flow regimes in horizontal pipelines. A particular experiment involved uses air and water at a temperature of 25°C, which flow through a horizontal glass tube with an internal diameter of 25.4 mm and a length of 40 m. Water is admitted at a controlled rate of 0.026 kgs-¹ at one end and air at a rate of 5 x 104 kgs¹ in the same direction. The density of water is 1000 kgm3, and the density of air is 1.2 kgm-³. Determine the mass flow rate, the mean density, gas void fraction, and the superficial velocities of the air and water. Answer: 0.02605 kgs-1, 61.1 kgm ³, 0.94, 0.822 ms-1, 0.051 ms-1arrow_forward
- Q=2000J Vout =? m (kg/s) D=0.1m air Air at (5.15x10^2) K flows out of a circular pipe at 101325 Pa as shown in Figure. The mass flowrate of the air at the pipe entrance is 0.0093 kg/s. The diameter of the pipe is 0.1m. Specific gas constant of air is 287 J/kg-K. Specific heat of air is 1000 J/kg-K. Find the outlet Velocity if 2000 J of heat is added to the pipe. Answer should be in m/s with three significant figures. Note: Your answer is assumed to be reduced to the highest power possible. Your Answer: x10 Answer DELLarrow_forwardQ=2000J =? out m (kg/s) D=0.1m air Air at (4.75x10^2) K flows out of a circular pipe at 101325 Pa as shown in Figure. The mass flowrate of the air at the pipe entrance is 0.0093 kg/s. The diameter of the pipe is 0.1m. Specific gas constant of air is 287 J/kg-K. Specific heat of air is 1000 J/kg-K. Find the outlet Velocity if 2000 J of heat is added to the pipe. Answer should be in m/s with three significant figures. Note: Your answer is assumed to be reduced to the highest power possible.arrow_forwardA liquid metal flows at a mass rate of 3 kg/s through a constant heat flux 5-cm-i.d tube in a nuclear reactor. The fluid at 473 K is to be heated with the tube wall 30 K above the fluid temperature. Determine the length of the tube required for a 1-K rise in bulk fluid temperature, using the following properties: p = 7.7 x 10^3 kg/m^3v = 8.0 x 10^-8 m^2/sCp = 130 J/(kg K)k = 12 W/mKPr = 0.011 Kaufman's correlation: Nu = 0,625.(Re.Pr)0,4arrow_forward
- A liquid while flowing through a thin-walled cylindrical copper pipe (D=10 cm, L=1 m) with a mass flow rate of 0.001 kg/s is heated from Ti= 33 °C to Te= 98 °C by supplying constant surface heat flux to the pipe surface (all the heat is transferred to the fluid). Considering fully developed laminar flow in the pipe, what is the surface temperature of the pipe at the exit in Celsius? (For the fluid use, Cp 1800 J/kg.K, k= 0.2 W/m.K) = constant 117111 q's m = 0.001 kg/s 111 L=1m D= 10 cmarrow_forwardA saturated steam at 410K is being transported in a pipeline (brass drawing tubing) at a rate of 1 grams/second. Pipe has inside diameter of 0.025 m . The tube is 100m long. The pressure at the entrance is 80kPa. (use Perry's Handbook for the properties and constants) R = 8314J/kg mol K; MW=18.02g/mol a. What is the value of G in kg/s.m2? b. What is the value of friction factor? c. What is the % of pressure drop? d. Calculate the outlet pressure.arrow_forwardQ=2000J 111111 Vout =? m (kg/s) D=D0.1m air Air at (5.00x10^2) K flows out of a dcular pipe at 101325 Pa as shown in Figure. The mass flowrate of the air at the pipe entrance is 0.0093 kg/s. The diameter of the pipe is 0.1m. Specific gas constant of air is 287 J/kg-K. Specific heat of air is 1000 J/kg-K. Find the outlet Velocity if 2000 J of heat is added to the pipe. Answer should be in m/s with three significant figures. Note: Your answer is assumed to be reduced to the highest power possible. Your Answer: Acti Go to x10 Answer W 9°C 2020arrow_forward